Did You Know?

 

Escherichia coli

 

Escherichia coli O157:H7 is a leading cause of foodborne illness. Based on a 1999 estimate, 73,000 cases of infection and 61 deaths occur in the United States each year.

 

CDC 

Article

ATP Bioluminescence for Rapid Detection of Microbial Contamination

 

By Jozsef Farkas

 

Bioluminescent ATP Assay

 

ATP (adenosine triphosphate) is the chemical compound in which energy is stored in all living cells. In the ATP-luminometric test the firefly enzyme (luciferase) in the presence of its substrate, luciferin, oxygen and magnesium ions catalyzes conversion of chemical energy of ATP into light through oxidation-reduction reaction. The quantity of light generated is directly proportional to the amount of ATP present, thus, the light units can be used to estimate the biomass of cells in a sample. With state of the art equipment, and highly purified reagents, it is possible to detect amounts of ATP corresponding to approximately 100 bacterial cells, although in practice it is usually nearer to 103-104. Quantification of intracellular microbial ATP can be conveniently accomplished using rapid and simplified extraction and assay procedures. The light emitted by this process can be monitored by a variety of luminometers. Supplying companies provide customers with test kits with all necessary reagents. The reagents are injected into the instruments and readout is reported in relative light units (RLUs). By knowing the number of microorganisms responsible for generating known RLUs, one can estimate the number of microorganisms in the (food) sample. The ATP method has been used to evaluate microbial loads in e.g. meat, milk, water, fruit juice samples in a winery and a brewery, and sweeteners and syrups (FUNG, 1997). Much interest has been developed also in using ATP estimation not for total viable cell counts but as a sanitation check including also the verification of somatic cells presence on a surface.

This version of the ATP bioluminescence method based on detecting all ATP on a surface provides an indication of cleanliness detecting also ATP of somatic origin that the traditional plate count method does not detect, instead of only of microbial origin (CHEN, 2000; ILLSLEY et al., 2000; QUINN et al., 2002; PAEZ et al., 2003). Samples for assessing surface hygiene by this method can be obtained by swabbing the surface, or by taking aliquots of the rinse water (KISS et al., 1999). Reading of the bio-luminometers may be assessed as "acceptable" or "unacceptable". The procedure can be easily performed by almost anyone, with little training. The preparation and measuring time takes only several minutes. Portable luminometer reading units have test swabs with pre-packaged reagents. The user swabs the surface to be tested, activates the swab by placing it into the solution of reagents then inserts it into the chamber of the luminometer to obtain the measurement.

ATP Bioluminescence for Rapid Detection of Microbial Contamination:  Created on December 3rd, 2007.  Last Modified on December 3rd, 2007
Disclaimer ↓

The Cleaning Industry Research Institute (CIRI) is a 501.c.3 not-for-profit scientific, educational and research organization that applies science to the practice and improvement of cleaning and maintenance.

 

This abstract/brief is presented under the recognized "fair use" doctrine with respect to article copyright and intellectual property. Readers are encouraged to secure the full article from the originating publication source. Articles also may be obtained through a librarian, an information specialist or inter-library loan. In cases where payment is required under copyright it can be processed through a reference library or the Copyright Clearance Center at www.copyright.com.

 

CIRI provides no warranty, expressed or implied, and assumes no legal liability for the accuracy, completeness or usefulness of any information disclosed on its site. The views and opinions of authors expressed herein do not necessarily reflect those of CIRI principals, executives, science advisors or affiliates.

 

Comments

Comments

Members

Member Access

Sorry, only CIRI Members are allowed to comment.

 

If you're a member, sign in:

Not a CIRI Member? Join Today to tap CIRI knowledge and networking resources

Sorry, there are currently no comments on this article...

About Jozsef Farkas

Prof. Dr. József Farkas is President of the Complex Committee on Food Science of the Hungarian Academy of Sciences, Budapest, Hungary.

 
 

 

 

 

Popular Topics: Swine Flu | H1N1 | MRSA | Staph | Norovirus | Flu | E. Coli | C. Difficile | Salmonella | Green Cleaning | Cleaning for Health | Nosocomial Infections | Disinfection | Bacteria | Viruses | Indoor Air Quality | Asthma | Allergies | Allergen | Mold

 

© 2007-2010 The Cleaning Industry Research Institute
A 501.c.3 not-for-profit scientific, educational and research institute
1988 Central Avenue
Albany, NY 12205

Phone: (888)285-2474
Fax: (518)456-6445
Privacy Policy | Shipping Policy | Return Policy & Procedure